ELISA Kit for Stercobilin (SB)
Product Specifications
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Assay Principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Stercobilin (SB) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Stercobilin (SB) and unlabeled Stercobilin (SB) (Standards or samples) with the pre-coated antibody specific to Stercobilin (SB) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Stercobilin (SB) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Stercobilin (SB) in the sample.
Assay Protocol
1. Prepare all reagents, samples and standards; <br/> 2. Add 50µ L standard or sample to each well.<br/> And then add 50µ L prepared Detection Reagent A immediately.<br/> Shake and mix. Incubate 1 hour at 37° C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100µ L prepared Detection Reagent B. Incubate 30 minutes at 37° C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 90µ L Substrate Solution. Incubate 10-20 minutes at 37° C; <br/> 7. Add 50µ L Stop Solution. Read at 450 nm immediately.<br/>
Assay Performance Time
2H
Sample Type
Serum, plasma, stool and other biological fluids
Detection Range
1.23 - 100 ng/mL
Precision
<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Stercobilin (SB) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Stercobilin (SB) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>
Sensitivity
The minimum detectable dose of this kit is typically less than 0.56ng/mL
Stability
<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>
Specificity
<p> This assay has high sensitivity and excellent specificity for detection of Stercobilin (SB) .<br/> No significant cross-reactivity or interference between Stercobilin (SB) and analogues was observed. </p>
Method
Competitive Inhibition
Organism Species
Pan-species (General)
CAS Number
7732-18-5
Available Sizes
Curated Selection
Explore Other Products
Discover premium biology products from our extensive collection of 20M+ items