CLIA Kit for Angiotensin I (AngI)

Product Specifications

Product Name Alternative

Ang-I; Angiotensin-1

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Angiotensin I (AngI) . A competitive inhibition reaction is launched between biotin labeled Angiotensin I (AngI) and unlabeled Angiotensin I (AngI) (Standards or samples) with the pre-coated antibody specific to Angiotensin I (AngI) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Angiotensin I (AngI) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Angiotensin I (AngI) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 50&micro; L standard or sample to each well.<br/> &nbsp; &nbsp; &nbsp; &nbsp; And then add 50&micro; L prepared Detection Reagent A immediately. <br/> &nbsp; &nbsp; &nbsp; &nbsp; Shake and mix. Incubate 1 hour at 37&deg; C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 7. Read RLU value immediately.<br/>

Assay Performance Time

2H

Sample Type

Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids

Detection Range

7.81 - 2000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Angiotensin I (AngI) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Angiotensin I (AngI) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 2.92pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Angiotensin I (AngI) .<br/> No significant cross-reactivity or interference between Angiotensin I (AngI) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Homo sapiens (Human)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

GM CSF Receptor alpha (CSF2RA) Mouse Monoclonal Antibody [Clone 2B2]
E45M20767V-2 50 ul

GM CSF Receptor alpha (CSF2RA) Mouse Monoclonal Antibody [Clone 2B2]

Ask
View Details
Rabbit Anti-PLXB1/PLXNB1 Polyclonal Antibody
PAV3089 100 μL

Rabbit Anti-PLXB1/PLXNB1 Polyclonal Antibody

Ask
View Details
CD1B CRISPR Activation Plasmid (h2)
sc-417718-ACT-2 20 µg

CD1B CRISPR Activation Plasmid (h2)

Ask
View Details
Tmem135 (NM_028343) Mouse Tagged ORF Clone
MG207317 10 µg

Tmem135 (NM_028343) Mouse Tagged ORF Clone

Ask
View Details
Mouse Monoclonal CD163L1 Antibody (CD163L1/7971) [DyLight 650]
NBP3-24128C 0.1 mL

Mouse Monoclonal CD163L1 Antibody (CD163L1/7971) [DyLight 650]

Ask
View Details