CLIA Kit for Mucin 5 Subtype AC (MUC5AC)

Product Specifications

Product Name Alternative

TBM; MUC5; LeB; Oligomeric Mucus/Gel-Forming; Mucin 5, Subtypes A And C, Tracheobronchial/Gastric; Gastric mucin; Lewis B blood group antigen; Major airway glycoprotein

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Mucin 5 Subtype AC (MUC5AC) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Mucin 5 Subtype AC (MUC5AC) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Mucin 5 Subtype AC (MUC5AC) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

13.7 - 10000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Mucin 5 Subtype AC (MUC5AC) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Mucin 5 Subtype AC (MUC5AC) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 5.1pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Mucin 5 Subtype AC (MUC5AC) .<br/> No significant cross-reactivity or interference between Mucin 5 Subtype AC (MUC5AC) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

mTNFSF14
cyt-826-01 5µg

mTNFSF14

Ask
View Details
mTNFSF14
cyt-826-02 20µg

mTNFSF14

Ask
View Details
mTNFSF14
cyt-826-03 1mg

mTNFSF14

Ask
View Details
ATOH1 (Atonal Homolog 1, ATH1, HATH1, MATH-1, BHLHa14) (AP)
MBS6134750-01 0.1 mL

ATOH1 (Atonal Homolog 1, ATH1, HATH1, MATH-1, BHLHa14) (AP)

Ask
View Details
ATOH1 (Atonal Homolog 1, ATH1, HATH1, MATH-1, BHLHa14) (AP)
MBS6134750-02 5x 0.1 mL

ATOH1 (Atonal Homolog 1, ATH1, HATH1, MATH-1, BHLHa14) (AP)

Ask
View Details
CYP4Z1 Antibody (N-term) [APR32517G]
APR32517G-01 50 µL

CYP4Z1 Antibody (N-term) [APR32517G]

Ask
View Details