Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Fibroblast Growth Factor 18 (FGF18)

Product Specifications

Product Name Alternative

ZFGF5

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 18 (FGF18) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 18 (FGF18) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor 18 (FGF18) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

1.37 - 1000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Fibroblast Growth Factor 18 (FGF18) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 0.49pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 18 (FGF18) .<br/> No significant cross-reactivity or interference between Fibroblast Growth Factor 18 (FGF18) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Rattus norvegicus (Rat)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

ZFP42 Peptide (AAP36244)
AAP36244-100UG 100 µg

ZFP42 Peptide (AAP36244)

Ask
View Details
Human WFDC13 Protein Lysate
MBS8429856-01 0.02 mg

Human WFDC13 Protein Lysate

Ask
View Details
Human WFDC13 Protein Lysate
MBS8429856-02 5x 0.02 mg

Human WFDC13 Protein Lysate

Ask
View Details
Rabbit anti-MCM2 Antibody
DL90727A-01 50 µL

Rabbit anti-MCM2 Antibody

Ask
View Details
Rabbit anti-MCM2 Antibody
DL90727A-02 100 µL

Rabbit anti-MCM2 Antibody

Ask
View Details
Rabbit Anti-Human DNAJC7 pAb
PA13122-01 50 μL

Rabbit Anti-Human DNAJC7 pAb

Ask
View Details