Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Interleukin 19 (IL19)

Product Specifications

Product Name Alternative

MDA1; ZMDA1, IL-10C, NG.1; Melanoma Differentiation Associated Protein-Like Protein

UniProt

Q9UHD0

Applications

Chemiluminescent immunoassay for Antigen Detection.

Field of Research

Cytokine; Infection immunity

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 19 (IL19) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 19 (IL19) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 19 (IL19) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2h, 40min

Sample Type

Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Detection Range

1.37-1,000pg/mL

Precision

Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Interleukin 19 (IL19) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Interleukin 19 (IL19) were tested on 3 different plates, 8 replicates in each plate. CV (%) = SD/meanX100 Intra-Assay: CV Inter-Assay: CV Inter-Assay: CV

Sensitivity

The minimum detectable dose of this kit is typically less than 0.53pg/mL

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Format

48T, 96T, 96Tx5, 96Tx10, 96Tx100

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 19 (IL19) . No significant cross-reactivity or interference between Interleukin 19 (IL19) and analogues was observed.

Product Name Synonym

Interleukin 19

Method

Double-antibody Sandwich

Organism Species

Homo sapiens (Human)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

GABRA3 3'UTR Lenti-reporter-Luc Vector
21154081 1.0 μg

GABRA3 3'UTR Lenti-reporter-Luc Vector

Ask
View Details
Anti-Zebrafish Mef2 Antibody Fluoro488 Conjugated
DZ01398-1-Fluoro488 200 µL/Vial

Anti-Zebrafish Mef2 Antibody Fluoro488 Conjugated

Ask
View Details
Goat Polyclonal PUM1 Antibody [DyLight 350]
NB100-259UV 0.1 mL

Goat Polyclonal PUM1 Antibody [DyLight 350]

Ask
View Details
ADPRHL2 Antibody
A12040-100UL 100 µL

ADPRHL2 Antibody

Ask
View Details