CLIA Kit for Indole 3 Acetic Acid (IAA)

Product Specifications

Product Name Alternative

IA-A; Indolylacetic Acid; Indoleacetic Acid; Heteroauxin

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Indole 3 Acetic Acid (IAA) . A competitive inhibition reaction is launched between biotin labeled Indole 3 Acetic Acid (IAA) and unlabeled Indole 3 Acetic Acid (IAA) (Standards or samples) with the pre-coated antibody specific to Indole 3 Acetic Acid (IAA) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Indole 3 Acetic Acid (IAA) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Indole 3 Acetic Acid (IAA) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 50&micro; L standard or sample to each well.<br/> &nbsp; &nbsp; &nbsp; &nbsp; And then add 50&micro; L prepared Detection Reagent A immediately. <br/> &nbsp; &nbsp; &nbsp; &nbsp; Shake and mix. Incubate 1 hour at 37&deg; C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 7. Read RLU value immediately.<br/>

Assay Performance Time

2H

Sample Type

Tissue or cell culture supernates

Detection Range

1.56 - 400 ng/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Indole 3 Acetic Acid (IAA) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Indole 3 Acetic Acid (IAA) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 0.59ng/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Indole 3 Acetic Acid (IAA) .<br/> No significant cross-reactivity or interference between Indole 3 Acetic Acid (IAA) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Pan-species (General)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Tpm1 (NM_001164254) Mouse Tagged ORF Clone
MG217021 10 µg

Tpm1 (NM_001164254) Mouse Tagged ORF Clone

Ask
View Details
ARHGAP11A (NM_001286480) Human Tagged ORF Clone
RG239650 10 µg

ARHGAP11A (NM_001286480) Human Tagged ORF Clone

Ask
View Details
Human Ro Protein 52 kDA (Ro52) AssayLite™ Antibody (PerCP Conjugate)
33235-05171 5x 30 µg

Human Ro Protein 52 kDA (Ro52) AssayLite™ Antibody (PerCP Conjugate)

Ask
View Details
PSL-75-3 AF Systems Consumables
101851 Pack of 250 Label(s)

PSL-75-3 AF Systems Consumables

Ask
View Details