Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Immunoglobulin A (IgA)

Product Specifications

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Immunoglobulin A (IgA) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Immunoglobulin A (IgA) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Immunoglobulin A (IgA) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma, saliva and other biological fluids

Detection Range

27.4 - 20000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Immunoglobulin A (IgA) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Immunoglobulin A (IgA) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 8.95pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Immunoglobulin A (IgA) .<br/> No significant cross-reactivity or interference between Immunoglobulin A (IgA) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Mus musculus (Mouse)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Mouse Monoclonal Cyclin D1 Antibody (OTI1G2) [DyLight 350]
NBP2-70244UV 0.1 mL

Mouse Monoclonal Cyclin D1 Antibody (OTI1G2) [DyLight 350]

Ask
View Details
STNL P017-450x150-PE-CRD/1 AC Signs
823972 Card of 1 Pictogram(s)

STNL P017-450x150-PE-CRD/1 AC Signs

Ask
View Details
TADA3 Over-expression Lysate Product
GWB-801393 0.1 mg

TADA3 Over-expression Lysate Product

Ask
View Details
Rdh7 (NM_017473) Mouse Untagged Clone
MC204504 10 µg

Rdh7 (NM_017473) Mouse Untagged Clone

Ask
View Details
Recombinant Debaryomyces hansenii Cofilin (COF1)
MBS1387757-01 0.05 mg (E-Coli)

Recombinant Debaryomyces hansenii Cofilin (COF1)

Ask
View Details
Recombinant Debaryomyces hansenii Cofilin (COF1)
MBS1387757-02 0.05 mg (Yeast)

Recombinant Debaryomyces hansenii Cofilin (COF1)

Ask
View Details