CLIA Kit for Corticosterone (Cort)

Product Specifications

Product Name Alternative

Corticosrone

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Corticosterone (Cort) . A competitive inhibition reaction is launched between biotin labeled Corticosterone (Cort) and unlabeled Corticosterone (Cort) (Standards or samples) with the pre-coated antibody specific to Corticosterone (Cort) . After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Corticosterone (Cort) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Corticosterone (Cort) level in the sample or standard.

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 50&micro; L standard or sample to each well.<br/> &nbsp; &nbsp; &nbsp; &nbsp; And then add 50&micro; L prepared Detection Reagent A immediately. <br/> &nbsp; &nbsp; &nbsp; &nbsp; Shake and mix. Incubate 1 hour at 37&deg; C; <br/> 3. Aspirate and wash 3 times; <br/> 4. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 5. Aspirate and wash 5 times; <br/> 6. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 7. Read RLU value immediately.<br/>

Assay Performance Time

2H

Sample Type

Serum, plasma, urine and other biological fluids

Detection Range

781 - 200000 pg/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Corticosterone (Cort) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Corticosterone (Cort) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 275pg/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Corticosterone (Cort) .<br/> No significant cross-reactivity or interference between Corticosterone (Cort) and analogues was observed. </p>

Method

Competitive Inhibition

Organism Species

Pan-species (General)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

CCR3 (NM_001837) Human Tagged ORF Clone Lentiviral Particle
RC210337L4V 200 µL

CCR3 (NM_001837) Human Tagged ORF Clone Lentiviral Particle

Ask
View Details
ACSS1 Polyclonal Antibody
MBS9432395-01 0.05 mL

ACSS1 Polyclonal Antibody

Ask
View Details
ACSS1 Polyclonal Antibody
MBS9432395-02 0.1 mL

ACSS1 Polyclonal Antibody

Ask
View Details
ACSS1 Polyclonal Antibody
MBS9432395-03 5x 0.1 mL

ACSS1 Polyclonal Antibody

Ask
View Details
Human NDNF shRNA Plasmid
abx962433-01 150 µg

Human NDNF shRNA Plasmid

Ask
View Details
Human NDNF shRNA Plasmid
abx962433-02 300 µg

Human NDNF shRNA Plasmid

Ask
View Details