Welcome to GenPrice! Check out our latest updates.

Shopping Cart (0)

Your cart is empty

Add some products to get started!

CLIA Kit for Myoglobin (MYO)

Product Specifications

Product Name Alternative

PVALB; MB

Applications

Chemiluminescent immunoassay for Antigen Detection.

Assay Principle

The microplate provided in this kit has been pre-coated with an antibody specific to Myoglobin (MYO) . Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Myoglobin (MYO) . Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Myoglobin (MYO) level in the sample or standard.;

Assay Protocol

1. Prepare all reagents, samples and standards; <br/> 2. Add 100&micro; L standard or sample to each well. Incubate 2 hours at 37&deg; C; <br/> 3. Aspirate and add 100&micro; L prepared Detection Reagent A. Incubate 1 hour at 37&deg; C; <br/> 4. Aspirate and wash 3 times; <br/> 5. Add 100&micro; L prepared Detection Reagent B. Incubate 30 minutes at 37&deg; C; <br/> 6. Aspirate and wash 5 times; <br/> 7. Add 100&micro; L Substrate Solution. Incubate 10 minutes at 37&deg; C; <br/> 8. Read RLU value immediately.<br/>

Assay Performance Time

2H, 40min

Sample Type

Serum, plasma, tissue homogenates and other biological fluids

Detection Range

0.27 - 200 ng/mL

Precision

<p> Intra-assay Precision (Precision within an assay) : 3 samples with low, middle and high level Myoglobin (MYO) were tested 20 times on one plate, respectively. <br/> Inter-assay Precision (Precision between assays) : 3 samples with low, middle and high level Myoglobin (MYO) were tested on 3 different plates, 8 replicates in each plate. <br/> CV (%) = SD/meanX100 <br/> Intra-Assay: CV<10% <br/> Inter-Assay: CV<12% <br/> </p>

Sensitivity

The minimum detectable dose of this kit is typically less than 0.10ng/mL

Stability

<p> The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. <br/> To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. </p>

Specificity

<p> This assay has high sensitivity and excellent specificity for detection of Myoglobin (MYO) .<br/> No significant cross-reactivity or interference between Myoglobin (MYO) and analogues was observed. </p>

Method

Double-Antibody Sandwich

Organism Species

Sus scrofa; Porcine (Pig)

Available Sizes

Curated Selection

Explore Other Products

Discover premium biology products from our extensive collection of 20M+ items

Anti-Tensin 2 Antibody
MBS8242848-01 0.03 mL

Anti-Tensin 2 Antibody

Ask
View Details
Anti-Tensin 2 Antibody
MBS8242848-02 0.05 mL

Anti-Tensin 2 Antibody

Ask
View Details
Anti-Tensin 2 Antibody
MBS8242848-03 0.1 mL

Anti-Tensin 2 Antibody

Ask
View Details
Anti-Tensin 2 Antibody
MBS8242848-04 0.2 mL

Anti-Tensin 2 Antibody

Ask
View Details
Anti-Tensin 2 Antibody
MBS8242848-05 5x 0.2 mL

Anti-Tensin 2 Antibody

Ask
View Details
S100A7A Antibody
DF9784-01 100 µL

S100A7A Antibody

Ask
View Details